Available Everyday · 7 min

Change two dimensions, with a volume limit

Change several dimensions in one reviewed run and state a measurement the result must meet. If it misses, you can't accept it.

Video in production

Until it is ready, this is the running order. Each step is also written out below, and you can try it in the simulator.

  1. Two bodies

    The plate and block in SOLIDWORKS; capture.

  2. Two changes

    Plate 10 to 12, then Additional dimension changes: block 6 to 8.

  3. The limit

    Tick volume; minimum, maximum, source.

  4. Pass

    Run on a copy; both checks pass; STEP shows 2 solids at 32,000 mm³.

  5. A miss

    Motion graphic: 31,200 mm³ fails and Accept is refused.

You need

  • You have done Change a dimension on a copy
  • A clean, saved, rebuilt part with one configuration and no equations or external references

You'll come away with

  • Propose up to 16 dimension changes at once
  • Set a volume, area or mass limit with its source
  • Know what happens when a limit is missed

Step by step

  1. Capture the part

    In Worksheets, write the brief and choose Capture current part and references.

    “Plate 10 to 12 mm thick. Separate block 6 to 8 mm. Keep both solids and their plan sizes.”

  2. Propose both changes

    Enter the first change, then use Additional dimension changes (up to 16 total) for the rest. Each must be a captured driving dimension, with a new positive value that differs from the old one.

  3. Add a measurement limit

    Under Required measurement limits, tick volume, area or mass. Enter a Minimum and a Maximum, and where the requirement comes from. Each measurement can be used once.

  4. Run it and read the limit

    Choose Save proposal for review, then Accept plan and execute on copy. The limit is checked after the rebuild and again after the native reopen, and marked pass, fail or unproven.

  5. Accept only a pass

    If every limit passes and the independent STEP check agrees, write your note and choose Accept result. Anything else fails the run, and acceptance is refused.

Try it here.

The part, both changes and the 32,000 mm³ result are from a recorded run on 23 September 2026. The limit values and the failing case are examples, labelled as such.

Solidworks Agent · design conversation simulated · step 1 of 5
  1. Captured

    Body 1
    60 × 40 mm plate, 10 mm thick
    Body 2
    20 × 20 mm block, 6 mm thick
    Volume before
    26,400 mm³

    24,000 + 2,400 = 26,400 mm³.

    Recorded from a real run

What it won't do

  • At most three limits, one each for volume, area and mass. Both bounds and a source are required.
  • Limits are optional. Without one, the run checks the dimensions and the STEP import only.
  • A limit shows the result meets a number you chose, not that the number is right.

Covers: Reviewed dimension changes. See the full index